127 x 76 x 13 Universal Beam
Home › Universal Beams › 127 x 76 x 13
The lightest beam in the standard universal beam range, and the one most often specified where the opening is modest and the load above it is light.
Get a price on this size
Send us your engineer’s drawings and we’ll work out quantities and price in one go — steel cut, drilled and finished to your specification and delivered direct to site.
127 x 76 x 13 dimensions and weight
| Size | Weight | Depth | Width | Web Thickness | Flange Thickness |
|---|---|---|---|---|---|
| (mm) | (kg/m) | (mm) | (mm) | (mm) | (mm) |
| 127 x 76 | 13 | 127 | 76 | 4.2 | 7.6 |
| Length | 6m | 7.5m | 9m | 12m |
|---|---|---|---|---|
| Total weight | 80kg | 100kg | 115kg | 155kg |
Approximate total weight by length — this is what determines how the beam is offloaded on site.
What is a 127 x 76 x 13 used for?
The 127 x 76 x 13 is the smallest section in the UB range and sits at the point where a steel beam starts to make more sense than a timber or concrete lintel. It turns up most often in small internal openings, short trimmer beams around stairwells and loft hatches, and light non-structural or lightly loaded partitions. At 13 kg per metre it is also the only UB in common use that two people can reasonably lift and position by hand over a short length, which is why builders reach for it on jobs with no crane access and tight interior stairs. It is not a beam for spanning open-plan rooms or carrying floor loads over any distance. If your engineer’s calculations are pushing toward 3 metres or the beam is picking up a floor as well as a wall, expect to move up to the 152 x 89 x 16.
Indicative span
Under typical UK domestic loading, published load tables place the 127 x 76 x 13 in the region of 2m to 2.5m. That assumes a simply supported beam with an evenly distributed load, an imposed load of around 1.5 kN/m² and a dead load of 0.5–0.8 kN/m².
Grades, lengths and finishes
The 127 x 76 x 13 is normally supplied to BS EN 10025-2 in S275JR or S355JR. S355 is the higher strength grade and is increasingly the default across the supply network; if your calculations specify one grade, tell us, because the two are not interchangeable. Mill certificates can be supplied with the order on request.
Beams are supplied cut to your lengths rather than as standard mill lengths, and we can arrange:
- Cutting to size — supplied ready to install, no cutting on site
- Drilling, notching and holes to your engineer’s details
- Welded cleats, end plates and connections
- Painting and priming, including intumescent coatings
- Galvanising for external or exposed applications
Delivery
A 6m length of 127 x 76 x 13 weighs approximately 80kg. That is within reach of manual handling over a short distance with enough people, though it is rarely pleasant. We deliver direct to site across London, the South and the Midlands, with HIAB lorry crane offload available on request. If access is restricted — a terraced street, a rear garden, limited headroom — tell us at quote stage rather than on the day, and we’ll plan the delivery around it.
Other sizes in the range
| Size | Weight | Indicative Span | |
|---|---|---|---|
| Next | 152 x 89 x 16 UB | 16 kg/m | 2.5–3.2m |
Also searched as: 127x76x13, 127 x 76 x 13 UB, UB 127x76x13, 127×76 RSJ. The term “RSJ” is still widely used for universal beams, though strictly it refers to the older rolled steel joist section with tapered flanges.
- All universal beam sizes
- Universal columns (UC) — where the load is vertical rather than spanning
- RSJ beams
- PFC parallel flange channels
Common questions
What does 127 x 76 x 13 actually mean?
The first two figures are the nominal depth and width of the section in millimetres — 127mm deep by 76mm wide. The third is the weight in kilograms per metre, 13kg/m. Actual depth and width vary slightly from the nominal serial size: this section measures 127mm by 76mm.
How much does a 127 x 76 x 13 weigh?
13kg per metre. A 6m length is therefore around 80kg. Add a margin for any end plates or cleats.
Can you cut it to length?
Yes. Beams are supplied cut to your specified lengths, so there’s no cutting on site. Send us the cutting list or the engineer’s drawings and we’ll price it cut, drilled and finished as required.
Is this the right size for my opening?
We can’t tell you that, and neither can a span table. Beam size depends on the loads it carries, the span, and how it’s restrained and supported — which is why Building Control requires calculations from a structural engineer. Once you have those, send them to us and we’ll price the steel.
Ready for a price?
Send your engineer’s drawings or a cutting list and we’ll come back with quantities and a price. Large and small orders both welcome.
Dimensional data shown is nominal and for guidance. Span figures are indicative and must not be used in place of structural calculations.